Skip to content
    • Contact
    • (02) 97486988
    • Contact
    • (02) 97486988
Domo-Technica AustraliaDomo-Technica Australia
  • About Us
  • Contact Us
  • 0
    Cart

    No products in the cart.

    Return to shop

  • Home
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Raysafe
    • X-Ray QA Instruments
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
  • Quantum Design
    • Material Science
    • Cryogenics
    • Optics
    • Nanoscience
    • Sample Synthesis
    • Biotechnology & Chemistry
    • Magnetic Separator
    • Laboratory Squids
  • Montana Instruments
    • Research Platforms
    • Measurement Systems
    • Integrated Solutions
    • Accessories
  • Calibration
    • Australia
    • New Zealand
  • All Products
Add to Wishlist
ProSim 2 and 3 Vital Signs Simulators
ProSim 2 and 3 Vital Signs Simulators - Image 2
ProSim 2 and 3 Vital Signs Simulators - Image 3
ProSim 2 and 3 Vital Signs Simulators - Image 4
Home / Fluke Biomedical / Patient Simulators

ProSim 2 and 3 Vital Signs Simulators

  • Fb-ps320_05b_c

The ProSim 2 and ProSim 3 Vital Signs Simulators are the clear choice for biomedical engineering and field service technicians that need a quality feature rich device with high portability.

Categories: Fluke Biomedical, Patient Simulators

  • Fb-ps320_05b_c
Browse
  • Fluke Biomedical
    • Defibrillator Analysers
    • Digital Pressure Meters
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Neonatal Test Equipment
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Montana Instruments
    • Accessories
    • Integrated Solutions
    • Measurement Systems
    • Research Platforms
  • Quantum Design
    • Biotechnology & Chemistry
    • Cryogenics
    • Laboratory Squids
    • Magnetic Separator
    • Material Science
    • Nanoscience
    • Optics
    • Sample Synthesis
    • SCL-Sensor.Tech – Self-Sensing Cantilevers
  • Raysafe
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
    • X-Ray QA Instruments
  • Uncategorised
  • Description
  • Features
  • Specifications
  • Models and Accessories

Don’t need a comprehensive patient monitor tester? The ProSim 3 and 2 Vital Signs Simulators are the clear choice for biomedical engineering and field service technicians that need a quality feature rich device with high portability.

What makes the ProSim 3 and 2 the best choice for testing in the field?

Light weight and equipped with enough battery life to last a full work day
Field upgradeable firmware
Simple user interface and stay connected ECG posts
Streamlined cable requirements with updated DIN connectors that ensure ProSim family consistency
Easily pairs with SPOT Light and other devices for comprehensive testing.

Features

Key Features:

  • Portable patient simulator for evaluating the performance of patient monitors
  • 20% lighter and 25% smaller than predicate devices
  • Just-right feature set includes ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/maternal (ProSim 3 only)
  • 43 high-quality ProSim 8 waveforms
  • With four IBP channels, ProSim 3 can test even the highest acuity scenarios
  • Improved hardware includes stay-connected ECG posts and upgraded DIN connectors
  • Simplified user interface with four button navigation
  • Field upgradeable, and easily paired with other devices for comprehensive testing

 

 

Specifications

General specifications
Temperature Operating 10 °C to 40 °C (50 °F to +104 °F)
Storage -25 °C to +50 °C

(-13 °F to +122 °F)

Humidity 10 % to 80 % non-condensing
Altitude 2,000 meters (6,562 ft)
Dimensions (LxWxH) 14.0 cm x 20.6 cm x 4.5 cm (5.5 in x 8.2 in x 1.8 in)
Display LCD greyscale display
Communication USB device upstream port
Power Two 9 V alkaline batteries
Battery life 8 hours continuous operation
Weight 0.47 kg (1 lb, 4 oz)
Safety standards IEC 61010-1, Pollution degree 2
Certifications CE, CSA, C-TICK N 10140, RoHS
Electromagnetic compatibility (EMC) IEC 61326-1; 2006
Detailed specifications
Normal-sinus-rhythm waveforms
ECG reference The ECG amplitudes specified are for Lead II (calibration), from the

baseline to the peak of the R wave. All other leads are proportional.

Normal sinus rhythm 12-lead configuration with independent outputs referenced to right

leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and

IEC Standards

Amplitude 0.05 mV to 0.45 mV (0.05 mV steps); 0.5 mV to 5.5 mV (0.5 mV steps)
Amplitude accuracy ± 2 % of setting Lead II. All other leads ± 5 %
ECG rate 30, 40, 45, 60, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260,

280 and 300 BPM

Rate accuracy ± 1 % of setting
ECG waveform selection Adult (80 ms) or pediatric (40 ms) QRS duration
ST-segment elevation Adult mode only: -0.8 mV to +0.8 mV (0.1 mV steps)
Additional steps: +0.05 mV and -0.05 mV
Power-on default 80 BPM, 1.0 mV, adult QRS, ST-segment elevation of 0 mV, and a P-R

interval of 0.16 seconds

Pacemaker waveform
Pacer pulse Amplitude 0 (off), 1, 2, 5, 10 mV ± 10 % for

lead II (reference lead) with other

leads proportional as for performance

waves.

Accuracy Reference lead II: ± (5 % setting

+ 0.2 mV)

Pacer pulse width 0.1, 0.5, 1.0, 1.5, 2.0 ms ± 5%
Paced arrhythmias Atrial 80 BPM
Asynchronous 75 BPM
Demand with frequent sinus beats
Demand with occasional sinus beats
Atrio-ventricular sequential
Noncapture (one time)
Nonfunction
Power-on default Off
Arrhythmia
Baseline NSR 80 BPM
PVC focus Left focus, standard timing (except where specified)
Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia;

missed beat (one time); atrial tachycardia; paroxysmal atrial tachycardia;

nodal rhythm; and supraventricular tachycardia

Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature

nodal contraction (PNC); PVC1 left ventricular; PVC1 left ventricular,

early; PVC1 left ventricular, R on T; PVC2 right ventricularl PVC2

right ventricular, early; PVC2 right ventricular, R on T; and multifocal

PVCs

Ventricular arrhythmia PVCs 6, 12, or 24 per minute; frequent multifocal PVCs; bigeminy;trigeminy; multiple PVCs (one-time run of 2, 5, or 11 PVCs); ventricular

tachycardia; ventricular fibrillation (coarse or fine); and asystole

Conduction defect First-, second-, or third-degree AV block; and right- or left-bundle branchblock
Power-on default None (off)
ECG performance testing
Amplitude 0.05 to 0.45 mV (0.05 mV steps), 0.5 to 5.5 mV (0.5 mV steps)
Pulse wave 30, 60 BPM, with 60 ms pulse width
Square wave 2.0, 0.125 Hz
Triangle wave 2.0, 2.5 Hz
Sine wave 0.5, 5, 10, 40, 50, 60, 100 Hz
R-wave detection wave form Haver-Triangle
R-wave rate 30, 60, 80, 120, 200, and 250 BPM
R-wave width 20 to 200 ms (10 ms steps) Additional Steps: 8, 10, and 12 ms
Rate accuracy ± 1%
Amplitude accuracy ±(2 % of setting + 0.05 mV) , Lead II (Exception: ±5 % for R waves ≤20 ms)
Power-on default None (off)
Fetal/Maternal ECG (ProSim 3 only)
Fetal heart rate (Fixed) 60, 90, 120, 140, 150, 210 and 240 BPM
Fetal heart rate (IUP) 140 BPM at beginning, then varies with pressure
Intrauterine-pressure waveforms Early deceleration, late deceleration, and uniform acceleration
Wave duration 90 seconds, bell-shaped pressure curve, from 0 to 90 mmHg and

returning to 0

IUP period 2, 3, or 5 minutes; and manual
Power-on default FHR 120 BPM, early deceleration, manual
Invasive blood pressure
Channels 4, each independently settable with identical parameters and are

individually electronically isolated from other signals

Input/output impedance 300 Ω ±  10 %
Exciter input range 2.0 to 16.0 V rms
Exciter-input frequency range DC to 5000 Hz
Transducer sensitivity 5 or 40 μV/V/mmHg
Pressure accuracy ± 2 % of setting + 2 mmHg (valid for dc excitation only)
Static Levels, Channel 1 -10, 0, 80, 160, 240, 320, 400 mmHg
Static Levels, Channel 2 -10, 0, 50, 100, 150, 200, 240 mmHg
Static Levels, Channel 3 (ProSim 3 only) -5, 0, 20, 40, 60, 80, 100 mmHg
Static Levels, Channel 4 (ProSim 3 only) -5, 0, 20, 40, 60, 80, 100 mmHg
Dynamic waveforms, Channel 1 Arterial: 120/80, Radial Artery: 120/80, Left ventricle: 120/00,

Right ventricle: 25/00

Dynamic waveforms, Channel 2 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00,

Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00,

Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2,

Left atrium: 14/4

Dynamic waveforms, Channel 3 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00,

Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00,

Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2,

Left atrium: 14/4

Dynamic waveforms, Channel 4 Swan-Ganz sequence, Right atrium (CVP), Right ventricle (RV),

Pulmonary artery (PA), Pulmonary-artery wedge (PAW

Respiration artifact BP delta changes from 3 to 16 mmHg
Output connector DIN 5-Pin
Power-on default 0 mmHg
Respiration
Rate 0 (OFF), 15, 20, 30, 40, 60, 80, 100, 120 BrPM
Waves Normal or ventilated
Ratio (inspiration: expiration) 1:1
Impedance variations (Δ Ω) 0.2, 0.5, 1 or 3 Ω peak-to-peak variation of lead impedance
Accuracy delta ± 10 %
Baseline 500, 1000, 1500, 2000 Ω, Leads I, II, III
Accuracy baseline ± 5 %
Respiration lead LA or LL
Apnea selection OFF, 12, 22 or 32 seconds (one-time events), or continuous (Apnea

ON = respiration OFF)

Power-on default 20 BrPM, delta 1.0 Ω, 1000 Ω baseline
Temperature
Temperature 0 °C (32 °F), 24 °C (75.2 °F), 37 °F (98.6 °C), and 40 °C (104 °F)
Accuracy ± 0.1° C
Compatibility Yellow Springs, Inc. (YSI) Series 400 and 700
Output connector Circular DIN 4-pin
Power-on default 0 °C (42 °F)
Cardiac output
Catheter type Baxter Edwards, 93a-131-7f
Calibration coefficient 0.542 (0 °C) injectate), 0.595 (24 °C injectate)
Blood temperature 37 °C (98.6 °F) ± 2 %
Injectate volume 10 cc
Injectate temperature 0 °C or 24 °C ±  2 % value
Cardiac output 2.5, 5, 10 liters per minute ± 5 %
Faulty-injectate curve Waveform for simulation available
Left-to-right shunt curve Waveform for simulation available
Calibrated pulse 1.5
Output connector DIN 7-PIN
Power-on default 2.5 liters perminute, 0 °C injectate

 

Models and Accessories

Model Name Description Price List
ProSim 2 (4318341)  

  • ProSim 2/3 Users Manual CD
  • Two 9-V alkaline batteries
  • IBP cable, unterminated
  • USB Cable
  • ProSim 2/3 Carrying Case
  • Power cord

 

ProSim 3 (4307790)  

  • ProSim 2/3 Users Manual CD
  • Two 9-V alkaline batteries
  • IBP cable, unterminated
  • 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box)
  • USB Cable
  • ProSim 2/3 Carrying Case
  • Power cord

 

 

Cables (IBP)
3010-0104 3010-0104 EM-1 BP cable (6ft) (6-pin) (part# 2198893)
For use with the following:
•GE Marquette Medical (PPG/E for M DR)
•Witt Biomedical
•Schiller PB Series
3010-0103 3010-0103 Datascope DS-1 BP cable (6F) (part# 2198887)
3010-0307 Fukuda Denshi (DS3300 series) FD-2 BP cable (12M) (12-pin orange) (part# 2199387)
3010-0357 GE Marquette Medical (Dash, Eagle, Solar, Tram and MacLab) MQ-3 BP cable (rectangular -11 M) (part# 2199627)
3010-0110 HP-3 BP cable (12M 5µV) 120 in, Mini-DIN to 12 pin HP/PH (part# 2198902)
For use with the following:
•Hewlett Packard/Philips (78-300, 78-500, 78-800, Merlin/Viridia/Omnicare)
(HP/Philips M1006B iBP module has a sensitivity of 5 uv/V/mmHg only. Select the HP-3 cable for this application)
2392173 IBP cable, unterminated (part# 2392173)
3010-0122 GE Marquette Medical (7000 and TRAM-AR series only) MQ-2 (8M round) (7-pin) (part# 2198978)
MiniDIN/DIN IBP Mini DIN to DIN IBP Adapter (part# 3408564)
•Nihon Kohden
Used to adapt PS420 or MPS450 blood pressure cables for use with ProSim series simulators.
3010-0116 PC-1 BP cable (6M) (6-pin) (part# 2198940)
For use with the following:
•Physio Control (VSM series)
•Medical Data Electronics (Escort series)
3010-0584 DX-1 BP cable (10F) (10-pin) (part# 2200955)
Used with the following:
•Puritan Bennett PB 240
•Datex (AS/3, CS/3, Compact, Cardio Cap II, Critical Care, Light)
3010-0248 QM-1 (6M) Blood pressure cable (10-pin orange) (part# 2198925)
for use with the following:
•Quinton (Q Cath series)
•Drager/Siemens
(Some of Drager/Siemens monitors use the standard 10 pin Siemen connector, but newer models require Drager’s IBP Adapter 10 to 7 pin. Drager PN: 3368383)
3010-0114 SM-1 BP cable (10M) for Pro Sim 2/3, 4 or ProSim 8 (10-pin) (part# 2198925)
•Drager/Siemens (SIRECUST series)
(Use the SM-1 and the Siemens Medical Transducer Adapter (3368-383-E530U) to run a single invasive BP channel on the Siemens Medical SC6000 and SC9000 series monitors)
3010-0048FG Universal unterminated UU-1 BP cable (5-Pin DIN one end only) (part# 2392173)

 

Batteries, Chargers, and Power Supply
2198785 AC Power Cord (Italy)
10A, 250V, CEI23-16 TO C13, 3X1MM, H05VVF, 2.5M, BLACK
2200241 AC Power Cord (Israel)
10A, 250V, SI1-16P TO C13, 3X1MM, H05VVF, 2.5M, BLACK
284174 AC Power Cord (USA)
10A, 125V, NEMA5-15 TO C13, 3X18AWG, SVT, 6FT, BLACK
4219453 AC/DC Power Supply for ProSim 2/3 (part# 4219453)
30w, 90-264 VAC, 15v@2A
658641 AC Power Cord (Australia)
10A, 250V, AS/NZS3112 TO C13, 3X1MM, H05VVF, 2.5M, BLACK
769422 AC Power Cord (Schuko)
10A, 250V, CEE7/7 TO C13, 3X1MM, H05VVF, 2M, BLACK
769448 AC Power Cord (Switzerland)
10A, 250V, SEV1011 TO C-13, 3X1MM, H05VVF, 2.5M, BLACK, 2.5M
769455 AC Power Cord (UK)
IEC, 2.5M, 10A@250V
782771 AC Power Cord (India)
10A, 250V, SANS164-1 TO C13, 3X1MM, 2.5M, BLACK
2200218 AC Power Cord (Denmark)
250V, 10A, AFSNIT107-2-D1 TO C13, 3X1MM, 2.5M, BLACK
614487 Two 9-V alkaline batteries (614487)

 

Cables
3010-0284 COA-1 Cardiac output adapter (Hewlett Packard)
1/4 Phone plug to 4 pin female audio connector
(HPT-2 also required for cardiac output simulation on HP patient-monitoring systems) (part# 2199240)
3010-0285 HPT-2 temperature adapter (2 pin) (part# 2199257)
(Hewlett Packard/Philips)(used with UT-1 for HP monitors)
(COA-1 also required for cardiac output simulation on HP patient-monitoring systems)
ProSim8-4402GECO ProSim8-4402GECO Cardiac Output Switch for GE (Marquette Eagle) (part# 4022300) for use with ProSim 2/3 and ProSim 8
USB Cable USB Cable
• for ProSim 2 & 3 (part# 1671807)
• for Impulse 6000D/7000DP (part# 1626219)
• for IDA-1S (part# 1626219)
• for IDA-5 (part# 4354452)
3010-0193 UT-2 Standard 1/4″ phone plug (compatible with YSI 700 series – 3 conductor) temperature cable (part# 2199019)
Use with the following:
•Spacelabs Ultraview (use adapter# 700-0031-00)
•GE Marquette (use adapter# 402015-005 or 402015-004)
•Welch Allyn/Propaq
UT-4 UT-4 Low profile, ¼ in phone plug, YSI 400 series compatible, two conductor (part# 2523334 or 3015280)
•HP/Philips
•SpaceLabs Ultraview (adapter# 700-0031-00)
•GE Marquette Eagle/Dash/Solar (adapter# 402015-005 or 402015-004)
•Drager Infinity
•Welch Allyn/Propaq
•Nihon Kohden (requires Nihon Kohden Smart Temperature Cable K961 for the latest series TR-6000)

 

Carrying Cases
9530-0072 Soft Vinyl Carrying Case (part# 2248623)

 

Service Manuals
4253882 ProSim 2/3 Users Manual CD (part# 4253882)

 

Miscellaneous Accessories
3010-0289FG CI-3 Cardiac output test module (part# 2392199)

 

Service Packages
Care Plans Request a quote

 

Related products

SigmaPaceTM 1000 External Pacemaker Analyser
Add to Wishlist
Quick View

Fluke Biomedical

SigmaPaceTM 1000 External Pacemaker Analyser

The SigmaPace™ 1000 is a powerful handheld tool with a comprehensive range of test suites, measurement algorithms and test loads – as specified by the external pacemaker manufacturers – to fulfill your testing requirements both quickly and efficiently.

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.
Add to Wishlist
Quick View

Fluke Biomedical

PS410 Cardiac and Arrythmia Simulator

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.

ESA615 Electrical Safety Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

ESA615 Electrical Safety Analyzer

The ESA615 Electrical Safety Analyzer brings fast and simple automated testing in the form of a portable analyzer to healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities.

Impulse 7010 Defibrillator Selectable Load Accessory
Add to Wishlist
Quick View

Fluke Biomedical

Impulse 7010 Defibrillator Selectable Load Accessory

As you know the Impulse 7000 can do the following defibrillator performance tests: ECG functionality tests, AED or Shock Advisory capability tests, Pacemaker tests, and charge- and synch-time tests.

DPM4 Parameter Testers
Add to Wishlist
Quick View

Fluke Biomedical

DPM4 Parameter Testers

DPM4 Parameter Tester is a highly accurate meter for testing a wide range of medical devices. Key features include its lightweight, compact size and battery operation

ProSim 4 Vital Signs Patient Simulator
Add to Wishlist
Quick View

Fluke Biomedical

ProSim 4 Vital Signs Patient Simulator

Designed to get you in and out of most locations in 60 seconds, this quick-check device tests 12-lead ECG, respiration, IBP and NIBP with an easy touch screen menu designed for troubleshooting fast. It is 90 % smaller and lighter than single-function patient simulators, provides one-tap testing for most patient monitor checks, and runs all day on a single battery charge.

ESA620 Electrical Safety Analyser
Add to Wishlist
Quick View

Fluke Biomedical

ESA620 Electrical Safety Analyser

The ESA620 Electrical Safety Analyzer represents the next generation in portable, manual test tool for the biomedical technician and clinical engineer that are performing tests on medical equipment.

INCU II Incubator - Radiant Warmer Analyzerfb-incu-2_03a_ko_0
Add to Wishlist
Quick View

Fluke Biomedical

INCU II Incubator – Radiant Warmer Analyzer

Testing incubators and radiant warmers regularly is essential to validate their performance and ensure the safety and comfort of infants.
The Fluke Biomedical INCU II Incubator/Radiant Warmer Analyzer simplifies testing and verifying baby incubators, transport incubators, and radiant warmers are safe and conform to global IEC 60601-2-19 and IEC 60601-2-21 performance standards.

Biomedical Test Equipment
graph-domotech

01 Biomedical

02 Diagnostic Imaging

03 Radiation Safety

04 Impact Indicators

05 Service & Calibration

Product Sites
  • Fluke Biomedical
  • Quantum Design
  • Montana Instruments
  • Hitachi-Aloka
  • IBP
  • Tristan Technology
  • MagnaBiosciences
  • IOG Products
Customer Care
  • About Us
  • Contact Us
  • Privacy Policy
  • Terms of Use
  • Sitemap
This website is proudly powered by the passionate team at Aleph IT!
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
  • Home
  • About Us
  • Contact Us
  • All Products
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Test Automation
  • Quantum Design
  • Montana Instruments
  • Login
  • Newsletter

Login


Lost your password?