Skip to content
    • Contact
    • (02) 97486988
    • Contact
    • (02) 97486988
Domo-Technica AustraliaDomo-Technica Australia
  • About Us
  • Contact Us
  • 0
    Cart

    No products in the cart.

    Return to shop

  • Home
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Raysafe
    • X-Ray QA Instruments
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
  • Quantum Design
    • Material Science
    • Cryogenics
    • Optics
    • Nanoscience
    • Sample Synthesis
    • Biotechnology & Chemistry
    • Magnetic Separator
    • Laboratory Squids
  • Montana Instruments
    • Research Platforms
    • Measurement Systems
    • Integrated Solutions
    • Accessories
  • Calibration
    • Australia
    • New Zealand
  • All Products
Add to Wishlist
GM Pancake Probe with Filter Set
Home / Fluke Biomedical

GM Pancake Probe with Filter Set

The Model 489-110FS used in combination with the Model 190 Survey Meter is especially useful for radiation leakage measurements encountered with x-ray emitting laboratory instruments or industrial research equipment, such as electron microscopes, and ion implanters.

Categories: Fluke Biomedical, Raysafe

Browse
  • Fluke Biomedical
    • Defibrillator Analysers
    • Digital Pressure Meters
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Neonatal Test Equipment
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Montana Instruments
    • Accessories
    • Integrated Solutions
    • Measurement Systems
    • Research Platforms
  • Quantum Design
    • Biotechnology & Chemistry
    • Cryogenics
    • Laboratory Squids
    • Magnetic Separator
    • Material Science
    • Nanoscience
    • Optics
    • Sample Synthesis
    • SCL-Sensor.Tech – Self-Sensing Cantilevers
  • Raysafe
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
    • X-Ray QA Instruments
  • Uncategorised
  • Description
  • Features
  • Specifications

The Model 489-110FS used in combination with the Model 190 Survey Meter is especially useful for radiation leakage measurements encountered with x-ray emitting laboratory instruments or industrial research equipment, such as electron microscopes, and ion implanters. For service personnel and laboratory technicians, the Model 190 and 489-110FS combination is invaluable for performing “as found” and “final check out” radiation leakage surveys, which are of major importance in any Quality Assurance or personnel safety program. The Model 190 and 489-110FS probe are excellent for gross counting surveys. Once a leak has been found, energy compensating filters can be employed to determine the true exposures.

Energy compensation filter set to determine true dose rate
High detection efficiency
Ergonomic design
Detachable probe cable
Easy to decontaminate

Features


Key Features

  • The GM Pancake Probe adapted to accept compensation filter set
  • Set of energy compensation filters to determine true exposure rate
  • Available as complete kit 190-110KT which includes GM Pancake Probe Filter Set (Model 489-110FS), Survey Meter (Model 190), instruction manual, and carrying ca

Key Features

The Victoreen Model 489-110FS consists of a GM Pancake Probe, which is a hand, held, thin window detector designed for use with the Model 190 Survey Meter, and is configured for operating convenience during table top and floor surveys, as well as surveys of personnel and equipment.

The Model 489-110FS includes the GM Pancake Probe, filter set, connecting cable, operating instructions and calibration certificate. If the Model 489-110FS is purchased as a second detector for the Model 190 Survey Meter, a Model 190060 Calibration Module is also required.

The GM Pancake Probe has been modified to accept a set of two “screw on” energy compensation filters, which permit actual energy compensated exposure rates to be determined.

A screen protects the thin mica probe window to facilitate rapid frisking of surfaces with reduced risk of window damage.

The open area of the hexagonal stainless steel screen is 86%. Replacement foam grip handles are available: Model 489-130-44.

A complete kit: Model 190-110KT (shown on next page) is available which includes the Model 489-110FS Probe, one filter set, the Model 190 Survey Meter, connecting cable with module, calibration certificate, operating instructions, and carrying case.


Model 190-110KT

Specifications

Product Specifications
Detector:
 Halogen-quenched “Pancake” GM tube
Radiation detected:
 Alpha above 3.5 MeV, beta above 35 keV, and gamma / x-ray above 6 keV, without filters
Operating voltage for 190:
 900 V
Window:
 15 cm2 (1.75 in Ø) mica, 1.4 to 2.0 mg/cm2
Overall accuracy:
 Within ± 20% for x-rays and gamma rays; 30 to 300 keV for probe and filters; within ± 10% 300 keV to 60Counfiltered
Typical background:
 30 CPM
Sensitivity:
 3500 CPM/mR/hr
Protective screen:
 Stainless steel, hexagonal pattern providing 86% open area
Construction:
 Probe housing is ABS plastic with foam grip handle
Filters:
 Set of two metal filters, housed in threaded aluminum
holders; Tin 3.5 mm and Copper 3.0 mm thick
Cable:
 Shielded cord; approximately 4.5 ft long, terminated with a
MHV connector
Dimensions
Detector housing:  2.50 (w) x 4.25 (d) x 0.88 in (h) (6.36 x 10.8 x 2.2 cm)
Handle:  1 in Ø x 6.25 in (d) (2.54 x 16.5 cm) (excluding connector)
Weight
 0.63 lb (0.28 kg) without cable or filters
Model 190 and 489-110FS combination
 Calibrated to within ± 10% accuracy full scale for 137Cs energies up to 80 mR/h exposure rates. Overall accuracy of 190/489-110FS / filters within 20% in the 30 to 300 keV energy range
Efficiency
 The Model 489-110FS Pancake Probe efficiency is shown below without filters. In a recent performance check, the numbers shown represent typical results obtained:
14C  5%
99Tc  12%
137Cs  24%
90Sr  59%
36Cl  26%
241Am  8%
129I  2%
230Th  15%
239Pu  12%
NOTE:  The efficiency formula used to calculate the % Efficiency is: Eff.%=(CPM x 100) / DPM

Related products

QA-ES III Electrosurgical Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

QA-ES III Electrosurgical Analyzer

Ensure ESU safety. Test all critical ESU functions with precise power, current, frequency, crest factor and load resistance ranges.

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.
Add to Wishlist
Quick View

Fluke Biomedical

PS410 Cardiac and Arrythmia Simulator

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.

ESA620 Electrical Safety Analyser
Add to Wishlist
Quick View

Fluke Biomedical

ESA620 Electrical Safety Analyser

The ESA620 Electrical Safety Analyzer represents the next generation in portable, manual test tool for the biomedical technician and clinical engineer that are performing tests on medical equipment.

190M Medical ScopeMeter® Portable Oscilloscope
Add to Wishlist
Quick View

Fluke Biomedical

190M Medical ScopeMeter® Portable Oscilloscope

The 190M Medical ScopeMeter® Portable Oscilloscope is a high-performance, portable oscilloscope built upon the legacy of Fluke and Fluke Biomedical oscilloscopes in partnership with real customers like you.

ProSim SPOT Light SpO2 Pulse Oximeter Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

ProSim SPOT Light SpO2 Pulse Oximeter Analyzer

Featuring an exclusive ergonomic design, the ProSim SPOT Light is the first comprehensive SpO2 functional tester to come in a handheld and easy-to-use device.

Fb-ps320_05b_c
Add to Wishlist
Quick View

Fluke Biomedical

PS320 Fetal Simulator

At week five, a fetus’ heart starts beating, increasing to 155 to 195 beats per minute prior to birth. The strength and number of beats can be measured by a fetal electronic monitor to determine whether a fetus is in distress. The PS320 fetal simulator mimics fetal and maternal heartbeats (ECG), along with uterine activity during labor to accurately test and troubleshoot fetal electronic monitors.

DPM4 Parameter Testers
Add to Wishlist
Quick View

Fluke Biomedical

DPM4 Parameter Testers

DPM4 Parameter Tester is a highly accurate meter for testing a wide range of medical devices. Key features include its lightweight, compact size and battery operation

DPM1B Pneumatic Transducer Tester
Add to Wishlist
Quick View

Fluke Biomedical

DPM1B Pneumatic Transducer Tester

The DPM1B Pneumatic Transducer Tester is designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form, and to generate pressure within the ± 300 mmHg range to assist in repair and quality control.

Biomedical Test Equipment
graph-domotech

01 Biomedical

02 Diagnostic Imaging

03 Radiation Safety

04 Impact Indicators

05 Service & Calibration

Product Sites
  • Fluke Biomedical
  • Quantum Design
  • Montana Instruments
  • Hitachi-Aloka
  • IBP
  • Tristan Technology
  • MagnaBiosciences
  • IOG Products
Customer Care
  • About Us
  • Contact Us
  • Privacy Policy
  • Terms of Use
  • Sitemap
This website is proudly powered by the passionate team at Aleph IT!
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
  • Home
  • About Us
  • Contact Us
  • All Products
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Test Automation
  • Quantum Design
  • Montana Instruments
  • Login
  • Newsletter

Login


Lost your password?