Skip to content
    • Contact
    • (02) 97486988
    • Contact
    • (02) 97486988
Domo-Technica AustraliaDomo-Technica Australia
  • About Us
  • Contact Us
  • 0
    Cart

    No products in the cart.

    Return to shop

  • Home
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Raysafe
    • X-Ray QA Instruments
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
  • Quantum Design
    • Material Science
    • Cryogenics
    • Optics
    • Nanoscience
    • Sample Synthesis
    • Biotechnology & Chemistry
    • Magnetic Separator
    • Laboratory Squids
  • Montana Instruments
    • Research Platforms
    • Measurement Systems
    • Integrated Solutions
    • Accessories
  • Calibration
    • Australia
    • New Zealand
  • All Products
Add to Wishlist
GM Pancake Probe
Home / Fluke Biomedical

GM Pancake Probe

Designed for use in conjunction with the ASM-990 Series and other standard GM survey meters, the 489-110D can detect alpha, beta, and gamma radiation. It is configured for operating convenience in table-top and floor surveys as well as surveys of personnel and equipment.

Categories: Fluke Biomedical, Raysafe

Browse
  • Fluke Biomedical
    • Defibrillator Analysers
    • Digital Pressure Meters
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Neonatal Test Equipment
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Montana Instruments
    • Accessories
    • Integrated Solutions
    • Measurement Systems
    • Research Platforms
  • Quantum Design
    • Biotechnology & Chemistry
    • Cryogenics
    • Laboratory Squids
    • Magnetic Separator
    • Material Science
    • Nanoscience
    • Optics
    • Sample Synthesis
    • SCL-Sensor.Tech – Self-Sensing Cantilevers
  • Raysafe
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
    • X-Ray QA Instruments
  • Uncategorised
  • Description
  • Features
  • Specifications

Designed for use in conjunction with the ASM-990 Series and other standard GM survey meters, the 489-110D can detect alpha, beta, and gamma radiation. It is configured for operating convenience in table-top and floor surveys as well as surveys of personnel and equipment. Prime applications for this probe include nuclear medicine counter tops and frisker stations, leakage detection for low energy diagnostic x-ray machines, geological and environmental surveys or any place where there exists the suspicion that some form of radiation is present, especially emergency response teams. For storage and carrying ease, the probe fits into the standard handle clip on a survey meter.

The GM probe comes in two configurations: 489-110D with an ABS plastic housing, MHV connector, and foam grip, or 489-110E with a BNC connector. This selection of connectors provides the ability to attach the GM probe to most GM survey meters on the market. Replacement foam grip handles are available: 489-130-44. This same probe design is available in a rugged metal housing as 489-110C.

Features

Key Features

  • All purpose GM Pancake Probe detects alpha, beta, gamma, and x-ray radiations
  • High detection efficiency
  • Lightweight, ergonomic design
  • Detachable probe cable
  • BNC or MHV connector
  • Easy to decontaminate

Specifications

Product Specifications
Detector
 Halogen-quenched “Pancake” GM tube
Type
 Pancake alpha, beta, gamma, and x-ray with thin pancake window
Radiation detected
 Alpha above 3.5 MeV, beta above 35 keV, gamma and x-ray above 6 keV
Applications
 • All purpose sensitive alpha, beta, and gamma and x-ray probe
• Nuclear medicine counter tops
• Detects leakage from diagnostic x-ray machines, especially mammography
• Geological surveys
• Scrap metal yards
• HAZMAT
Typical background (shielded)
 30 CPM
Maximum exposure rate
 80 mR/h (800 µSv/hr)
Nominal sensitivity to 1 mR/hr of 60Co
 3500 CPM
Replacement GM tube part number
 P-115
Wall material
 Stainless steel with mica window
Wall thickness
 1.5 to 2.0 mg/cm2
Window
 15 cm2 (1.75 in Ø) mica, 1.4 to 2.0 mg/cm2
Active length
 1.5 in Ø (38mm)
Quenching gas
 Neon & halogen
Operating voltage
 900 V
Compatibility
 Compatible w/ all GM survey meters
Humidity range
 0 to 95%
Operating temperature range
 – 65° to + 185°F (- 56° to + 85°C)
Pressure range
 To 5 psig
Protective Screen
 Stainless steel, hexagonal pattern providing 89% open area
Construction
 ABS plastic housing and foam grip handle
Cable
 Shielded cord, approximately 4.5 ft long MHV coaxial connector or BNC connector
Dimensions
Detector housing:  2.5 (w) x 4.25 (d) x 0.875 in (h) (6.36 x 10.8 x 2.2 cm)
Handle:  1 in Ø x 6.25 in (d) (2.5 x 16.5 cm) (excluding connector)
Diameter of probe:  2.6875 in (68 mm)
Length of probe:  9.75 in (248 mm)
Weight
 Approx. 1 lb (0.45 kg)
Efficiency
 The GM Pancake Probe efficiency is shown below. In a recent performance check, the numbers shown represent typical results obtained:
14C  5%
99Tc  12%
137Cs  24%
90Sr  59%
36Cl  26%
241Am  8%
129I  2%
230Th  15%
239Pu  12%
NOTE:  The efficiency formula used to calculate the % Efficiency is: Eff.%=(CPM x 100) / DPM

Related products

ESA609 Electrical Safety Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

ESA609 Electrical Safety Analyzer

The ESA609 Electrical Safety Analyzer is a rugged, portable and easy-to-use analyzer designed for general electrical safety testing. Engineered for on-the-go technicians, the ESA609 requires no training to use and has a rubberized case that allows it to sustain the rigor of transportation, and helps prevent damage when accidentally dropped.

IDA-5 Infusion Pump Tester and Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

IDA-5 Infusion Pump Tester and Analyzer

Fast, accurate and proven infusion device analyzer helps increase productivity

Based on sophisticated measurement technology trusted by biomedical professionals around the world, the IDA-5 is a multi-channel infusion device analyzer that can test up to 4 infusion pumps at once. The IDA-5 has built-in automation allowing users to create custom test templates for quick, standardized testing of IV pump devices with minimal user intervention.

ESA612 Electrical Safety Analyser
Add to Wishlist
Quick View

Fluke Biomedical

ESA612 Electrical Safety Analyser

The ESA612 Electrical Safety Analyzer represents the next generation in test equipment for biomedical and clinical engineering professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator, multimeter and electrical safety tester in a single test tool.

IDA-1S Infusion Device Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

IDA-1S Infusion Device Analyzer

Test a wide variety of infusion pumps quickly and accurately.

Impulse 6000D Defibrillator Analyzer
Add to Wishlist
Quick View

Fluke Biomedical

Impulse 6000D Defibrillator Analyzer

The Impulse 6000D model is a Defibrillator Analyzer is a portable, rugged, easy-to-carry device with an intuitive user interface, backlight, and easy-to-read display.

ProSim 8 Vital Signs Patient Simulator
Add to Wishlist
Quick View

Fluke Biomedical

ProSim 8 Vital Signs Patient Simulator

Get the all-in-one multifunction vital signs simulator to ensure your devices provide the ultimate in patient safety.

Fb-ps320_05b_c
Add to Wishlist
Quick View

Fluke Biomedical

PS320 Fetal Simulator

At week five, a fetus’ heart starts beating, increasing to 155 to 195 beats per minute prior to birth. The strength and number of beats can be measured by a fetal electronic monitor to determine whether a fetus is in distress. The PS320 fetal simulator mimics fetal and maternal heartbeats (ECG), along with uterine activity during labor to accurately test and troubleshoot fetal electronic monitors.

INCU II Incubator - Radiant Warmer Analyzerfb-incu-2_03a_ko_0
Add to Wishlist
Quick View

Fluke Biomedical

INCU II Incubator – Radiant Warmer Analyzer

Testing incubators and radiant warmers regularly is essential to validate their performance and ensure the safety and comfort of infants.
The Fluke Biomedical INCU II Incubator/Radiant Warmer Analyzer simplifies testing and verifying baby incubators, transport incubators, and radiant warmers are safe and conform to global IEC 60601-2-19 and IEC 60601-2-21 performance standards.

Biomedical Test Equipment
graph-domotech

01 Biomedical

02 Diagnostic Imaging

03 Radiation Safety

04 Impact Indicators

05 Service & Calibration

Product Sites
  • Fluke Biomedical
  • Quantum Design
  • Montana Instruments
  • Hitachi-Aloka
  • IBP
  • Tristan Technology
  • MagnaBiosciences
  • IOG Products
Customer Care
  • About Us
  • Contact Us
  • Privacy Policy
  • Terms of Use
  • Sitemap
This website is proudly powered by the passionate team at Aleph IT!
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
  • Home
  • About Us
  • Contact Us
  • All Products
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Test Automation
  • Quantum Design
  • Montana Instruments
  • Login
  • Newsletter

Login


Lost your password?