Skip to content
    • Contact
    • (02) 97486988
    • Contact
    • (02) 97486988
Domo-Technica AustraliaDomo-Technica Australia
  • About Us
  • Contact Us
  • 0
    Cart

    No products in the cart.

    Return to shop

  • Home
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Raysafe
    • X-Ray QA Instruments
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
  • Quantum Design
    • Material Science
    • Cryogenics
    • Optics
    • Nanoscience
    • Sample Synthesis
    • Biotechnology & Chemistry
    • Magnetic Separator
    • Laboratory Squids
  • Montana Instruments
    • Research Platforms
    • Measurement Systems
    • Integrated Solutions
    • Accessories
  • Calibration
    • Australia
    • New Zealand
  • All Products
Add to Wishlist
Scintillation Pancake Probe
Home / Fluke Biomedical

Scintillation Pancake Probe

The Geiger-Mueller (GM) detectors fulfill a wide variety of radiation measurement needs. Probes are available for detection of alpha, beta, and gamma radiation. Some probes are provided with a 360° shield to permit discrimination between penetrating and non-penetrating radiation.

Categories: Fluke Biomedical, Raysafe

Browse
  • Fluke Biomedical
    • Defibrillator Analysers
    • Digital Pressure Meters
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Neonatal Test Equipment
    • Patient Simulators
    • Phototherapy Radiometer
    • Rigid Endoscope Tester
    • Test Automation
  • Montana Instruments
    • Accessories
    • Integrated Solutions
    • Measurement Systems
    • Research Platforms
  • Quantum Design
    • Biotechnology & Chemistry
    • Cryogenics
    • Laboratory Squids
    • Magnetic Separator
    • Material Science
    • Nanoscience
    • Optics
    • Sample Synthesis
    • SCL-Sensor.Tech – Self-Sensing Cantilevers
  • Raysafe
    • Phantoms and Test Tools
    • Radiation Safety
    • Real-Time Personal Dosimeter
    • X-Ray QA Instruments
  • Uncategorised
  • Description
  • Features
  • Specifications

The Geiger-Mueller (GM) detectors fulfill a wide variety of radiation measurement needs. Probes are available for detection of alpha, beta, and gamma radiation. Some probes are provided with a 360° shield to permit discrimination between penetrating and non-penetrating radiation.

Reliability and ruggedness are built into the GM detectors, with uniformity of construction and field-proven design to assure dependable performance with all the GM survey instruments. Standard MHV type connectors readily allow interchange of all detector probes. The GM counters are fastened to the Model 190 Count Rate and Survey Meter by a Velcro® strap. The life expectancy of the counters ranges from 108 total counts to unlimited life depending on the type of quench gas utilized. Enhanced sensitivity to low-level alpha, beta, gamma and x-ray radiation is achieved when using the unique Model 498-110D Pancake GM Probe.

The scintillation detectors are carefully selected and optically coupled to photomultiplier tubes. The photomultipliers are magnetically shielded with mu-metal and specially shock mounted to provide trouble-free performance. The entire detector, crystal and photomultiplier, are secured in sturdy, cylindrical, aluminum housing. Where appropriate, a thin window has been utilized to provide alpha or low energy gamma response.

Features


Key Features

The GM probes provide a qualitative assessment for radiation detection. The following probe selection guide lists various probes and suggested applications. Applications include nuclear medicine counter top surveys, leakage detection from diagnostic x-ray and linear accelerators, geological surveys, scrap metal yards and unknown wells.

The scintillation detectors provide a quantitative assessment for radiation detection in counts/minutes. Applications outlined in this guide include nuclear medicine labs, HAZMAT spills, radiation safety office surveys, industrial hygiene, industrial x-ray manufacturing, and geological surveys.

  • GM probes for qualitative radiation detection
  • Scintillation probes for quantitative radiation assessment
  • All probes are direct read when married with Models 190 and 290 meters
  • Rugged and reliable designs
  • Scintillators are test selected and optically coupled to PMT
  • GM probes re available in pancake style, energy compensated and with beta discrimination

Specifications

36515 36515 Product Specifications
Type:
NaI (Tl) Pancake, scintillator optically coupled to PMT
Radiation detected:
Gamma and x-ray above 25 keV, beta above 100 keV
Applications:
• Beta, gamma frisker for nuclear medicine is 10 times more sensitive than GM probe
• Environmental surveys
Typical background (CPM):
3000
Nominal sensitivity:
650 CPM/µR/hr 137Cs
Wall material:
0.04 in Al, 1 mm thick
Window:
130 mg/cm2 Al
Sensitive area:
59.2 cm2
Crystal dim.:
2 x 2 x 0.5 in
Probe diameter:
2.25 x 0.69 in
Probe length:
11 in
Cable length:
48 in
Operating voltage:
900 V
Calibration:
137Cs 2 pts/scale to 10 mR/hr
Cal. Tolerance:
± 10%
Efficiency:
90 SR 5%
137Cs 11%
133Ba 34%
60Co 16 %
Humidity range:
0 to 95%
Operating temp:
– 40° to + 120°F; – 40° to + 50°C; Max. temp increase of 20°F/hr
Weight (approx.):
0.78 lb (0.35 kg)

Related products

ProSim 4 Vital Signs Patient Simulator
Add to Wishlist
Quick View

Fluke Biomedical

ProSim 4 Vital Signs Patient Simulator

ProSim 4 Vital Signs Simulator with breakthrough touchscreen technology offers quick and simple one-tap testing for patient monitor performance checks and troubleshooting

DPM1B Pneumatic Transducer Tester
Add to Wishlist
Quick View

Fluke Biomedical

DPM1B Pneumatic Transducer Tester

The DPM1B Pneumatic Transducer Tester is designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form, and to generate pressure within the ± 300 mmHg range to assist in repair and quality control.

190M Medical ScopeMeter® Portable Oscilloscope
Add to Wishlist
Quick View

Fluke Biomedical

190M Medical ScopeMeter® Portable Oscilloscope

The 190M Medical ScopeMeter® Portable Oscilloscope is a high-performance, portable oscilloscope built upon the legacy of Fluke and Fluke Biomedical oscilloscopes in partnership with real customers like you.

DPM2Plus Universal Pressure Meter
Add to Wishlist
Quick View

Fluke Biomedical

DPM2Plus Universal Pressure Meter

The DPM2Plus Universal Pressure Meter is designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form to assist in repair and quality control.

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.
Add to Wishlist
Quick View

Fluke Biomedical

PS410 Cardiac and Arrythmia Simulator

This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.

DPM4 Parameter Testers
Add to Wishlist
Quick View

Fluke Biomedical

DPM4 Parameter Testers

DPM4 Parameter Tester is a highly accurate meter for testing a wide range of medical devices. Key features include its lightweight, compact size and battery operation

ESA620 Electrical Safety Analyser
Add to Wishlist
Quick View

Fluke Biomedical

ESA620 Electrical Safety Analyser

The ESA620 Electrical Safety Analyzer represents the next generation in portable, manual test tool for the biomedical technician and clinical engineer that are performing tests on medical equipment.

INCU II Incubator - Radiant Warmer Analyzerfb-incu-2_03a_ko_0
Add to Wishlist
Quick View

Fluke Biomedical

INCU II Incubator – Radiant Warmer Analyzer

Testing incubators and radiant warmers regularly is essential to validate their performance and ensure the safety and comfort of infants.
The Fluke Biomedical INCU II Incubator/Radiant Warmer Analyzer simplifies testing and verifying baby incubators, transport incubators, and radiant warmers are safe and conform to global IEC 60601-2-19 and IEC 60601-2-21 performance standards.

Biomedical Test Equipment
graph-domotech

01 Biomedical

02 Diagnostic Imaging

03 Radiation Safety

04 Impact Indicators

05 Service & Calibration

Product Sites
  • Fluke Biomedical
  • Quantum Design
  • Montana Instruments
  • Hitachi-Aloka
  • IBP
  • Tristan Technology
  • MagnaBiosciences
  • IOG Products
Customer Care
  • About Us
  • Contact Us
  • Privacy Policy
  • Terms of Use
  • Sitemap
This website is proudly powered by the passionate team at Aleph IT!
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
  • Home
  • About Us
  • Contact Us
  • All Products
  • Fluke Biomedical
    • Defibrillator Analysers
    • Electrical Safety Analysers
    • Electrosurgery Analysers
    • Gas Flow Analysers
    • Neonatal Test Equipment
    • Infusion Device Analysers
    • Medical ScopeMeter
    • Digital Pressure Meters
    • Patient Simulators
    • Phototherapy Radiometer
    • Test Automation
  • Quantum Design
  • Montana Instruments
  • Login
  • Newsletter

Login


Lost your password?