RaySafe ThinX X-ray DetectorAn easy tool for fast resultsRaySafe ThinX has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kVp, HVL, exposure time and pulses. All parameters are conveniently displayed in the large LCD. Active CompensationThanks to the RaySafe Active Compensation technology, no further corrections are required regarding variations in beam filtration to both kVp and dose measurements. Multiple sensors and advanced calculations automatically determine the beam quality, thereby eliminating the need for further corrections of measured kVp and dose values. The solid state sensor technology enables maximum accuracy whilst making measurements as effortless as possible. How it worksSimply position the meter under the X-ray beam and make an exposure. The display shows all measured values. 1. Position intra / position rad2. Expose3. Read out
|
RaySafe ThinX X ray detector
RaySafe ThinX has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kVp, HVL, exposure time and pulses.
Features
Fully automatic user interfaceThe main advantage of the RaySafe ThinX is that it provides a fully automatic user interface. Simply, there are no keys on the RaySafe ThinX. No set-up. No settings. No range selection. It’s all automatic. Just position and expose. Utilizing Auto ON/OFF, the RaySafe ThinX turns itself on when radiation is detected! With an unequalled battery life of more than 1 year, there is literally no maintenance needed. The RaySafe ThinX, being small and easy to use, is a perfect choice for radiation measurements in radiographic applications. In spite of its small size, it is packed with world-leading, state-of-the-art technology to make your measurements effortless. There is no need to worry about manual corrections for added filtration. The meter uses RaySafe’s exclusive Active Compensation to apply corrections for variations in beam filtration to both kVp and dose measurements.
|
Specifications
|
Models and Accessories
|
Related products
Fluke Biomedical
The Geiger-Mueller (GM) detectors fulfill a wide variety of radiation measurement needs.
Get all the benefits of state-of the-art features in a compact, hand held unit. Become a “speed reader with this accurate, rugged portable Clamshell Densitometer.
Raysafe
One of the specifications and chief features of an x-ray tube is its focal spot size, a very important factor in the resolution to be achieved during a radiologic examination.
Raysafe
Adjustable stand for focal spot measurement
The 84-317 Multipurpose Tissue/Cyst Ultrasound Phantom helps provide both quantitative and qualitative information on the performance of all diagnostic ultrasound-imaging systems.
Dual-Diode Dosimeter Patient Dose Monitor provides instant patient data on radiation exposure to sensitive organs and rapid checks of equipment output
The Mammography Accreditation Phantom will assist you in complying with MQSA and the American College of Radiology (ACR) Quality Control Programs.
Six range indicators (1, 2, 4, 8, 16, and 32 mR/hr) clearly display an increase or decrease in radiation levels.