RaySafe ThinX X-ray DetectorAn easy tool for fast resultsRaySafe ThinX has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kVp, HVL, exposure time and pulses. All parameters are conveniently displayed in the large LCD. Active CompensationThanks to the RaySafe Active Compensation technology, no further corrections are required regarding variations in beam filtration to both kVp and dose measurements. Multiple sensors and advanced calculations automatically determine the beam quality, thereby eliminating the need for further corrections of measured kVp and dose values. The solid state sensor technology enables maximum accuracy whilst making measurements as effortless as possible. How it worksSimply position the meter under the X-ray beam and make an exposure. The display shows all measured values. 1. Position intra / position rad2. Expose3. Read out
|
RaySafe ThinX X ray detector
RaySafe ThinX has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kVp, HVL, exposure time and pulses.
Features
Fully automatic user interfaceThe main advantage of the RaySafe ThinX is that it provides a fully automatic user interface. Simply, there are no keys on the RaySafe ThinX. No set-up. No settings. No range selection. It’s all automatic. Just position and expose. Utilizing Auto ON/OFF, the RaySafe ThinX turns itself on when radiation is detected! With an unequalled battery life of more than 1 year, there is literally no maintenance needed. The RaySafe ThinX, being small and easy to use, is a perfect choice for radiation measurements in radiographic applications. In spite of its small size, it is packed with world-leading, state-of-the-art technology to make your measurements effortless. There is no need to worry about manual corrections for added filtration. The meter uses RaySafe’s exclusive Active Compensation to apply corrections for variations in beam filtration to both kVp and dose measurements.
|
Specifications
|
Models and Accessories
|
Related products
The auto-ranging 451P ion chamber radiation survey meter features a pressurized ionization chamber, providing enhanced sensitivity (µR resolution) and improved energy response to measure radiation rate and dose from x-ray and gamma sources.
The auto-ranging 451B ion chamber survey meter measures radiation rate and accumulated dose from beta, gamma and x-ray radiation sources.
The Mammography Accreditation Phantom will assist you in complying with MQSA and the American College of Radiology (ACR) Quality Control Programs.
Fluke Biomedical
The 06-912 Dosimeter Charger is used for zeroing direct-reading dosimeters.
Raysafe
Tests and analysis of digital and analogue radiography and fluoroscopy equipment
This versatile phantom was designed to assist in training technologists and physicians in the use of a stereotactic system, and for verifying the proper operation of mammographic stereotactic biopsy systems.
Fluke Biomedical
The 451EXL provides remote control for many of the 451B and 451P functions via a Microsoft® Excel-based user interface, including real-time data logging with user defined alarm parameters, upload of the internal data log into Excel worksheet, real-time virtual instrument display, and accumulated dose measurement over a user defined integration period.
Six range indicators (1, 2, 4, 8, 16, and 32 mR/hr) clearly display an increase or decrease in radiation levels.