The RaySafe Pro-Digi Radiography phantom is a multi-functional phantom designed for digital radiography equipment constancy tests. It is used for analyzing beam alignment, dynamic range, contrast resolution, spatial resolution, and homogeneity. The versatility of the phantom enables to bring only this phantom for the image quality check and it also reduces amount of exposures and time spent while performing the needed tests. The phantom complies with the standards IEC 61223-3-1, DIN 6868-58 and DIN 6868-13.
RaySafe Pro-Digi Radiography Phantom
Beam alignment, dynamic range, contrast resolution, spatial resolution and homogeneity analysis
Features
The Pro-Digi measures the following:
Collimation/beam alignment
Dynamic range
Spatial resolution
Contrast resolution
Homogeneity
The Pro-Digi radiography phantom is equipped with a durable case with additional compartments for the included accessories, and complies with IEC 61223-3-1, DIN 6868-58 and DIN 6868-13. CE certified.
Specifications
Specifications:
Dimensions: 300 x 300 x 12 mm
1 mm thick copper plate embedded in PMMA
7-step copper wedge
6 low contrast elements
Free area for signal calibration and dose measurements
Markings to determine the size and position of the effective radiation field
Pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm)
Marks for correct orientation
Cone for perpendicular X-Ray beam control in the range of 0° ÷ 15°
25 mm aluminum filter – patient equivalent
Bucky mounting device for chest wall mounting
Models and Accessories
|
Related products
Dual-Diode Dosimeter Patient Dose Monitor provides instant patient data on radiation exposure to sensitive organs and rapid checks of equipment output
Fluke Biomedical
The 06-912 Dosimeter Charger is used for zeroing direct-reading dosimeters.
The auto-ranging 451P ion chamber radiation survey meter features a pressurized ionization chamber, providing enhanced sensitivity (µR resolution) and improved energy response to measure radiation rate and dose from x-ray and gamma sources.
Raysafe
Pediatric/Adult head and body
CTDI and x-ray scatter measurements
Raysafe
One of the specifications and chief features of an x-ray tube is its focal spot size, a very important factor in the resolution to be achieved during a radiologic examination.
Raysafe
The RaySafe DXR+, Direct X-ray Ruler, represents the latest in today’s technology for alignment of the light and radiation field.
Raysafe
RaySafe ThinX has been optimized to meet the need for a basic multi-parameter instrument for simultaneous measurement of dose, dose rate, kVp, HVL, exposure time and pulses.
Fluke Biomedical
Direct-Reading Pocket Dosimeters are rugged, precision instruments designed specifically for measuring accumulated quantities of gamma and x radiation.