The RaySafe Pro-Digi Radiography phantom is a multi-functional phantom designed for digital radiography equipment constancy tests. It is used for analyzing beam alignment, dynamic range, contrast resolution, spatial resolution, and homogeneity. The versatility of the phantom enables to bring only this phantom for the image quality check and it also reduces amount of exposures and time spent while performing the needed tests. The phantom complies with the standards IEC 61223-3-1, DIN 6868-58 and DIN 6868-13.
RaySafe Pro-Digi Radiography Phantom
Beam alignment, dynamic range, contrast resolution, spatial resolution and homogeneity analysis
Features
The Pro-Digi measures the following:
Collimation/beam alignment
Dynamic range
Spatial resolution
Contrast resolution
Homogeneity
The Pro-Digi radiography phantom is equipped with a durable case with additional compartments for the included accessories, and complies with IEC 61223-3-1, DIN 6868-58 and DIN 6868-13. CE certified.
Specifications
Specifications:
Dimensions: 300 x 300 x 12 mm
1 mm thick copper plate embedded in PMMA
7-step copper wedge
6 low contrast elements
Free area for signal calibration and dose measurements
Markings to determine the size and position of the effective radiation field
Pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm)
Marks for correct orientation
Cone for perpendicular X-Ray beam control in the range of 0° ÷ 15°
25 mm aluminum filter – patient equivalent
Bucky mounting device for chest wall mounting
Models and Accessories
|
Related products
Fluke Biomedical
The Geiger-Mueller (GM) detectors fulfill a wide variety of radiation measurement needs. Probes are available for detection of alpha, beta, and gamma radiation.
The small size of the phantom permits fast, easy comparison of conventional and digital image quality, because you can attain an image of the entire unit in a single exposure.
Fluke Biomedical
Direct-Reading Pocket Dosimeters are rugged, precision instruments designed specifically for measuring accumulated quantities of gamma and x radiation.
Raysafe
Pediatric/Adult head and body
CTDI and x-ray scatter measurements
Raysafe
Tests and analysis of digital and analogue radiography and fluoroscopy equipment
Fluke Biomedical
The 06-912 Dosimeter Charger is used for zeroing direct-reading dosimeters.
Six range indicators (1, 2, 4, 8, 16, and 32 mR/hr) clearly display an increase or decrease in radiation levels.
Raysafe
Adjustable stand for focal spot measurement