The PS410 is a compact high-performance arrhythmia cardiac simulator for patient monitor testing. This handheld device simulates a full range of cardiac rhythms and a wide variety of ECG conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms. Small enough to fit in a pocket, the handy PS410 weighs less than a pound and is easy to operate. Technicians simply connect the simulator to the device under test and use the PS410 keypad to enter the code presets. The simulator then transmits the selected preset simulations to the device.
PS410 Cardiac and Arrythmia Simulator
This handheld device simulates a full range of cardiac rhythms and a wide variety of electrocardiogram conditions. It includes pacemaker simulation, 35 arrhythmia selections, and adult and pediatric normal-sinus rhythms.
Features
- Compact, lightweight, pocket-sized
- Easy top-panel control
- 12-lead Electrocardiogram
- Adult and pediatric normal-sinus rhythms
- 35 arrhythmia selections
- Electrocardiogram performance waveforms
- ST segment levels
- Pacemaker simulation
- Electrocardiogram artifact
- Battery operated
- PS410/DPM1B Bundle Kit with custom carrying case for quick Electrocardiogram/non-invasive blood pressure testing
Specifications
|
Models and Accessories
|
Related products
Fluke Biomedical
The ESA612 Electrical Safety Analyzer represents the next generation in test equipment for biomedical and clinical engineering professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator, multimeter and electrical safety tester in a single test tool.
Fluke Biomedical
As you know the Impulse 7000 can do the following defibrillator performance tests: ECG functionality tests, AED or Shock Advisory capability tests, Pacemaker tests, and charge- and synch-time tests.
Fluke Biomedical
Testing incubators and radiant warmers regularly is essential to validate their performance and ensure the safety and comfort of infants.
The Fluke Biomedical INCU II Incubator/Radiant Warmer Analyzer simplifies testing and verifying baby incubators, transport incubators, and radiant warmers are safe and conform to global IEC 60601-2-19 and IEC 60601-2-21 performance standards.
Fluke Biomedical
The VT900A Gas Flow Analyzer provides the highest accuracy for testing gas flow and respiratory medical equipment.
Fluke Biomedical
The ESA615 Electrical Safety Analyzer brings fast and simple automated testing in the form of a portable analyzer to healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities.
Fluke Biomedical
The DPM2Plus Universal Pressure Meter is designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form to assist in repair and quality control.
Fluke Biomedical
The Impulse 6000D model is a Defibrillator Analyzer is a portable, rugged, easy-to-carry device with an intuitive user interface, backlight, and easy-to-read display.
Fluke Biomedical
At week five, a fetus’ heart starts beating, increasing to 155 to 195 beats per minute prior to birth. The strength and number of beats can be measured by a fetal electronic monitor to determine whether a fetus is in distress. The PS320 fetal simulator mimics fetal and maternal heartbeats (ECG), along with uterine activity during labor to accurately test and troubleshoot fetal electronic monitors.