The RaySafe Pro-Digi Radiography phantom is a multi-functional phantom designed for digital radiography equipment constancy tests. It is used for analyzing beam alignment, dynamic range, contrast resolution, spatial resolution, and homogeneity. The versatility of the phantom enables to bring only this phantom for the image quality check and it also reduces amount of exposures and time spent while performing the needed tests. The phantom complies with the standards IEC 61223-3-1, DIN 6868-58 and DIN 6868-13.
RaySafe Pro-Digi Radiography Phantom
Beam alignment, dynamic range, contrast resolution, spatial resolution and homogeneity analysis
Features
The Pro-Digi measures the following:
Collimation/beam alignment
Dynamic range
Spatial resolution
Contrast resolution
Homogeneity
The Pro-Digi radiography phantom is equipped with a durable case with additional compartments for the included accessories, and complies with IEC 61223-3-1, DIN 6868-58 and DIN 6868-13. CE certified.
Specifications
Specifications:
Dimensions: 300 x 300 x 12 mm
1 mm thick copper plate embedded in PMMA
7-step copper wedge
6 low contrast elements
Free area for signal calibration and dose measurements
Markings to determine the size and position of the effective radiation field
Pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm)
Marks for correct orientation
Cone for perpendicular X-Ray beam control in the range of 0° ÷ 15°
25 mm aluminum filter – patient equivalent
Bucky mounting device for chest wall mounting
Models and Accessories
|
Related products
The small size of the phantom permits fast, easy comparison of conventional and digital image quality, because you can attain an image of the entire unit in a single exposure.
Fluke Biomedical
The 451EXL provides remote control for many of the 451B and 451P functions via a Microsoft® Excel-based user interface, including real-time data logging with user defined alarm parameters, upload of the internal data log into Excel worksheet, real-time virtual instrument display, and accumulated dose measurement over a user defined integration period.
Dual-Diode Dosimeter Patient Dose Monitor provides instant patient data on radiation exposure to sensitive organs and rapid checks of equipment output
Six range indicators (1, 2, 4, 8, 16, and 32 mR/hr) clearly display an increase or decrease in radiation levels.
Fluke Biomedical
The 06-912 Dosimeter Charger is used for zeroing direct-reading dosimeters.
CTDI and scatter measurements
Raysafe
Tests and analysis of digital and analogue radiography and fluoroscopy equipment
Raysafe
Pediatric/Adult head and body
CTDI and x-ray scatter measurements